← Search recalls
NHTSARecalled 2016-12-23

Gillig, LLC — FUEL SYSTEM, OTHER

Is my product affected?

2016 GILLIG LOW FLOOR; 2015 GILLIG LOW FLOOR

  • Brand GILLIG

Check against the official notice below — it lists the full affected range.

What happened

Gillig LLC is recalling certain model year 2015-2016 Low Floor compressed natural gas (CNG) transit buses manufactured between September 1, 2015, and December 5, 2016, that are equipped with Amerex SafetyNet fire suppression system panel/controller units. The gas detection electronics in these buses may become disabled without alerting the driver, preventing the operator from receiving a fault code indicating a system malfunction. This defect could increase the risk of asphyxiation, fire, or explosion if a natural gas leak occurs and goes undetected.

Gillig is notifying affected bus owners and will provide free replacement of the Operator Display Panel/Controllers through Amerex representatives. The recall process began on January 20, 2017. Owners of affected buses should contact Gillig customer service at 1-800-735-1500 to arrange the replacement.

Written by software from the official notice below. Not reviewed by a lawyer.

Hazard

If not corrected, the fire suppression systems on certain CNG-powered buses may fail to indicate the presence of a natural gas (methane) leak. In such cases, the driver will not receive a fault code indicating that the Gas Detection electronics have been disabled. This may increase the risk of asphyxiation, fire, or explosion.

What should I do?

Gillig will notify owners, and Amerex representatives will replace the Operator Display Panel/Controllers, free of charge. The recall began January 20, 2017. Owners may contact Gillig customer service at 1-800-735-1500.

Details from the source

Gillig LLC (Gillig) is recalling certain model year 2015-2016 Low Floor compressed natural gas (CNG) transit buses manufactured September 1, 2015, to December 5, 2016, equipped with Amerex SafetyNet fire suppression system panel/controller units. These buses have gas detection electronics that may be disabled without providing the operator with a warning of a system malfunction. Affected display panel/controller units were also provided as replacement parts for warranty claims, part numbers 16389, 24109, 24918, 24926 and 24927.

Source

Official record: NHTSA ↗

Republished from the official source above; details can change — the source record controls.

Related recalls

All NHTSA recalls

Hurt by this product? Start a free Case Check

ProductRisk is not a law firm and does not provide legal services or legal advice. ProductRisk is a free consumer product-safety information service operated by Plaintify, Inc., a technology company. If you ask to be connected with a law firm, any legal services are provided by that firm — not by ProductRisk or Plaintify.