Aladin Air X NitrOx dive domputers
Check against the official notice below — it lists the full affected range.
UWATEC AG is recalling Aladin Air X NitrOx dive computers manufactured in 1995 due to a software defect. The software may inaccurately calculate desaturation times, which could result in decompression sickness during aggressive diving conditions. The affected dive computers are blue and black with "Aladin" and "NitrOx" printed on the front, and can be identified by checking the back of the unit in the lower right corner for a date code showing the month and year of manufacture (for example, "01.95" for January 1995). Only dive computers manufactured in 1995 are affected by this recall.
According to the recall notice, consumers should immediately stop using these dive computers and contact UWATEC for a free replacement. UWATEC will provide the current model, Aladin Air Z NitrOx, as a replacement unit.
Written by software from the official notice below. Not reviewed by a lawyer.
Software in the dive computers may inaccurately calculate desaturation times, resulting in possible decompression sickness under aggressive dive conditions.
Consumers should stop using these dive computers immediately and contact UWATEC for a free replacement. Consumers will receive the current model, Aladin Air Z NitrOx.
This recall involves Aladin Air X NitrOx dive computers manufactured in 1995. The manufacture date is located on the back of the dive computer, in the lower right hand corner. The date code reads the number of the month followed by a decimal point and the year, for example, "01.95." The dive computers are blue and black with the words "Aladin" and "NitrOx" printed across the front. Aladin Air X NitrOx dive computers with date codes other than "95" are not included in this recall.
Official record: U.S. Consumer Product Safety Commission ↗
Republished from the official source above; details can change — the source record controls.