2000 GIRARDIN MB II; 2001 GIRARDIN MB II; 1999 GIRARDIN MB IV; 1999 GIRARDIN MB II; 2001 GIRARDIN MB IV; 2000 GIRARDIN MB IV
Check against the official notice below — it lists the full affected range.
Corp. Micro Bird is recalling certain model year 1999 through 2001 Girardin MB II and MB IV school buses built on Ford and GM cutaway chassis between August 2, 1999, and May 31, 2001, that are equipped with a Trans/Air TA73 evaporator. The evaporator contains a power resistor that regulates blower speed. If a short occurs in the low or medium speed circuit while the blower is in high speed, the resistor can overheat to the point where it melts and ignites the plastic blower housing, potentially causing a fire.
To remedy this issue, Corp. Micro Bird and Trans/Air will install a thermal shutdown device in series with the speed resistors at no charge. The recall began on January 11, 2011. Owners of affected buses should contact the Trans/Air Warranty and Service Center at 1-800-673-2446 to arrange for the free service installation.
Written by software from the official notice below. Not reviewed by a lawyer.
THIS WOULD CAUSE THE RESISTOR TEMPERATURE TO RISE TO A POINT WHERE IT WILL MELT AND POSSIBLY IGNITE THE PLASTIC BLOWER HOUSING TO WHICH IT IS MOUNTED. THE OVERHEATING CAN RESULT IN A FIRE.
CORP. MICRO BIRD IN COOPERATION WITH TRANS/AIR WILL INSTALL A THERMAL SHUTDOWN DEVICE IN SERIES WITH THE SPEED RESISTORS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON JANUARY 11, 2011. OWNERS MAY CONTACT TRANS/AIR WARRANTY AND SERVICE CENTER AT 1-800-673-2446.
CORP. MICRO BIRD IS RECALLING CERTAIN MODEL YEAR 1999 THROUGH 2001 GIRARDIN MB II AND MB IV SCHOOL BUSES BUILT ON FORD AND GM CUTAWAY CHASSIS FROM AUGUST 2, 1999, THROUGH MAY 31, 2001, AND EQUIPPED WITH A TRANS/AIR TA73 EVAPORATOR. THE EVAPORATOR UTILIZES A POWER RESISTOR TO REGULATE BLOWER SPEED. SHOULD A SHORT OCCUR IN THE "LOW OR MEDIUM SPEED" CIRCUIT WHILE THE BLOWER IS IN HIGH SPEED, THE SHORT WILL CAUSE THE SUPPLY VOLTAGE TO FEEDBACK THROUGH THE RESISTOR TO GROUND, NOT DRAWING ENOUGH CURRENT TO TRIP THE FUSE.
Republished from the official source above; details can change — the source record controls.