← Search recalls
EU Safety GateRecalled 2021-06-25serious risk

Passenger car (Mitsubishi)

Is my product affected?

Passenger car

  • Brand Mitsubishi

Check against the official notice below — it lists the full affected range.

What happened

Mitsubishi is recalling certain passenger car models including the ASX, Eclipse Cross, Eclipse Cross PHEV, Outlander, and Outlander PHEV due to a software defect in the Forward Collision Mitigation (FCM) system. The improper software in the FCM ECU can cause camera images to be processed incorrectly, potentially triggering false collision detection. When the system incorrectly detects a collision, it may activate the vehicle's primary braking system, which increases the risk of an accident.

According to the recall notice, Mitsubishi as the manufacturer is conducting a recall to remove the affected vehicles from end users. The record does not specify what remedy or corrective action consumers should take to address this defect.

Written by software from the official notice below. Not reviewed by a lawyer.

Hazard

Due to improper software of the FCM ECU (Forward Collision Mitigation), camera images might be processed incorrectly and a possible collision might be detected falsely. As a result. the FCM system might operate primary braking, leading to increased risk of an accident. The product does not comply with the requirements laid down in the Regulation on the approval and market surveillance of motor vehicles and their trailers, and of systems, components and separate technical units intended for such vehicles.

What should I do?

Type of economic operator taking notified measure(s): ManufacturerCategory of measure(s): Recall of the product from end usersDate of entry into force: Unknown

Details from the source

Model codes: ASX (GA0W), Eclipse Cross (GK0W), Eclipse Cross PHEV (GL3W), Outlander (GF0W), Outlander PHEV (GG0W) Name: ASX, Eclipse Cross, Eclipse Cross PHEV, Outlander, Outlander PHEV Model: e1*2001/116*0406*29; e1*2001/116*0406*31; e1*2001/116*0406*32; e1*2001/116*0406*33; e1*2007/46*0368*15; e1*2007/46*0368*19; e1*2007/46*0368*21; e1*2007/46*0368*22; e1*2007/46*1769*00; , e1*2007/46*1769*01; e1*2007/46*1769*02; e1*2007/46*1769*04; e1*2007/46*1769*05; e1*2007/46*1769*06; e1*2007/46*176 Notifying country: Poland

Source

Official record: EU Safety Gate ↗

Republished from the official source above; details can change — the source record controls.

Related recalls

All EU Safety Gate recalls

Hurt by this product? Start a free Case Check

ProductRisk is not a law firm and does not provide legal services or legal advice. ProductRisk is a free consumer product-safety information service operated by Plaintify, Inc., a technology company. If you ask to be connected with a law firm, any legal services are provided by that firm — not by ProductRisk or Plaintify.