← Search recalls
EU Safety GateRecalled 2010-02-12serious risk

Inverter - Power Inverter (TITAN)

Is my product affected?

Inverter - Power Inverter

  • Brand TITAN

Check against the official notice below — it lists the full affected range.

What happened

The TITAN brand power inverter model HW-150 (barcode 4260120534816) has been recalled due to safety defects that pose an electric shock risk. The inverter has insufficient basic insulation, and its design allows a pin to be inserted into the socket on one side while live electrical parts remain accessible on the other side. The product fails to meet required European safety standards for low-voltage equipment and electrical safety.

Authorities in Hungary have ordered the product withdrawn from the market. The record does not specify what remedy is available to consumers who have already purchased this product.

Written by software from the official notice below. Not reviewed by a lawyer.

Hazard

The product poses a risk of electric shock because: - basic insulation of the inverter is insufficient;- a pin can be inserted on one side into the socket while the other live part is accessible.The product does not comply with the Low Voltage Directive (LVD) and the relevant European standards EN 60884 and EN 60950

What should I do?

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Details from the source

Main components: plug (JENN FENG 15 A 250 V), two-core cable (CSA TYPE SPT-2 2/C 1.31 mm² (16 AWG) 105 °C 300 V FT2 LL59042 LF (12-6) (UL) E89204 SPT-2 2/C 16 AWG 105 °C 300 V FTS TA TONG), inverter with metal and plastic cover, supplied with a switch and fan-cooling, socket (Wonpro 16 A 250 V). Technical parameters: Continuous Power 150 W, Peak Power 300 W, DC Input Voltage 10.5-15 V, Input Current 20 A, Input No Load Current 0.2 A, Output Voltage 230Vrms ac ± 10% Modified Sine Wave, Efficiency 85-95% Model: HW-150, bar code: 4260120534816 Notifying country: Hungary

Source

Official record: EU Safety Gate ↗

Republished from the official source above; details can change — the source record controls.

Related recalls

All EU Safety Gate recalls

Hurt by this product? Start a free Case Check

ProductRisk is not a law firm and does not provide legal services or legal advice. ProductRisk is a free consumer product-safety information service operated by Plaintify, Inc., a technology company. If you ask to be connected with a law firm, any legal services are provided by that firm — not by ProductRisk or Plaintify.