FDA (Device enforcement)Recalled 2025-05-21class i

Covidien: Newport HT70 Ventilator, REF: HT70M-JP-NA, HT70M-CN-NA, HT70M-ES-EU, HT70M-PT-BR, HT70M-SY-EU, HT70M-WW-EU, HT70M-WW-NA, HT70-SY-EU. Newport HT70Plus Ventilator, REF: HT70PM-ES-EU, HT70PM-ES

Hazard

Ventilator Printed Circuit Board Assembly may have two separate capacitors that may fail, which may result in the ventilator either shutting down during use, thus necessitating use of an alternate form of ventilation, or the shutdown alert alarm fails to alarm effectively during shut down, which may result in respiratory failure, hypoventilation, low oxygen saturation, hypoxia, treatment delay.

Details from the source

Reason for recall: Ventilator Printed Circuit Board Assembly may have two separate capacitors that may fail, which may result in the ventilator either shutting down during use, thus necessitating use of an alternate form of ventilation, or the shutdown alert alarm fails to alarm effectively during shut down, which may result in respiratory failure, hypoventilation, low oxygen saturation, hypoxia, treatment delay. Distribution: Worldwide - US Nationwide distribution including in the states of MA, CT, KS, OH, PR, NH, GA, WI, MS, VA, CO, TX, MN, AL, IA, NY, UT, NM, KY, RI, SD, PA, IA, CA, MO, HI, MI, IL, MT, NJ, TN, SC, FL, IN, AZ, ID, LA, WA, NC, MD, WY, NE, NV, ND, ME, AK, DE, OK, OR and the countries of Japan, Canada, Singapore, Lithuania, Kazakhstan, Slovenia, Colombia, China, Qatar, United Arab Emirates, Greece, Saudi Quantity: 4842 Lot/code info: REF/UDI-DI/Serial Numbers: HT70M-JP-NA/00839935008221/N10HT700710132, N10HT700710135, N10HT700710136, N10HT700710159, N10HT700710161, N10HT700710162, N10HT700710163, N10HT700710164, N10HT700810194, N10HT700810199, N10HT700810202, N10HT700810204, N10HT700810205, N10HT700810206, N10HT700910223, N10HT700910227, N10HT701010279, N10HT701011015, N10HT701011016, N10HT701111044, N10HT701111048, N10HT701111049, N10HT701111050, N11HT700111137, N11HT700111139, N11HT700111141, N11HT700111142, N11HT700111143, N11HT700111144, N11HT700211145, N11HT700211155, N11HT700211160, N11HT700211161, N11HT700211163, N11HT700211164, N11HT700311168, N11HT700311169, N11HT700311170, N11HT700311183, N11HT700311184, N11HT700311185, N11HT700311186, N11HT700311188, N11HT700311189, N11HT700311191, N11HT700311192, N11HT700311193, N11HT700311195, N11HT700311196, N11HT700311197, N11HT700311201, N11HT700311202, N11HT700311203, N11HT700311204, N11HT700311207, N11HT700311208, N11HT700311209, N11HT700311233, N11HT700311234, N11HT700311243, N11HT700311244, N11HT700311245, N11HT700311246, N11HT700311247, N11HT700311248, N11HT700311250, N11HT700311251, N11HT700311253, N11HT700311255, N11HT700411256, N11HT700411257, N11HT700411258, N11HT700411262, N11HT700411263, N11HT700411264, N11HT700411265, N11HT700411266, N11HT700411267, N11HT700411268, N11HT700411271, N11HT700411277, N11HT700411278, N11HT700411279, N11HT700411282, N11HT700411284, N11HT700411285, N11HT700411286, N11HT700411287, N11HT700411288, N11HT700411289, N11HT7

UPC codes

00839935008221, 10884521542044, 10884521542051, 10884521542082, 10884521542105, 10884521542136, 10884521542143, 10884521544178, 10884521542174, 10884521544291, 10884521544307, 10884521542181, 00839935009457, 10884521544338, 10884521542204, 10884521197855, 10884521208940, 10884521544376, 10884521542242, 10884521542259, 10884521542273, 10884521544369, 10884521542228

Source

Official record: FDA (Device enforcement)

Republished from the official source above; details can change — the source record controls.

Hurt by this product? Start a free Case Check

ProductRisk is not a law firm and does not provide legal services or legal advice. ProductRisk is a free consumer product-safety information service operated by Plaintify, Inc., a technology company. If you ask to be connected with a law firm, any legal services are provided by that firm — not by ProductRisk or Plaintify.

Privacy · Plaintify