Halogen heater
Check against the official notice below — it lists the full affected range.
The Dyras halogen heater (Model QHT-408) poses a risk of electric shock due to inadequate earth protection on the front. The screws connecting metal parts are not secured against loosening, the electrical resistance exceeds required standards, and basic insulated wires contact metal parts that lack proper earthing. The product does not comply with the Low Voltage Directive or European standard EN 60335.
Authorities have ordered withdrawal of this product from the market and recall from consumers. The source does not specify what action affected consumers should take in response to this recall.
Written by software from the official notice below. Not reviewed by a lawyer.
This product poses a risk of electric shock because the earth protection on the front part is not appropriate (the screws connecting metal parts are not secured against loosening, the resistance is higher than required by the standard) and the basic insulated wires contact metal parts that are not supplied with earthing. The product does not comply with the Low Voltage Directive and the relevant European standard EN 60335.
Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market and recall from consumers ordered by the authoritiesDate of entry into force: Unknown
The heater has white plastic cover, on the front the heating elements are covered with metal grids. Main parts of the luminaire: mains cable (YA TAI WIRE INDUSTRY Co., LTD., H05VV-F 3G0.75mm2, VDE); mains plug (Y003, 250V, 16A, +marks of approval); speed switch (JINHE Electrics, 25T125, PA66, 250VAC, 15A, + marks of approval); safety switch (KW3-0Z, 16A, 250VAC, CQC VDE, CE). Technical parameters: 230V; 50 Hz; 800W; Class I. Model: QHT-408 Notifying country: Hungary
Official record: EU Safety Gate ↗
Republished from the official source above; details can change — the source record controls.