← Search recalls
EU Safety GateRecalled 2008-02-08serious risk

Table lamps - 2 cylindrical table lamps "Present Light" (Kitten Dream)

Is my product affected?

Table lamps - 2 cylindrical table lamps "Present Light"

  • Brand Kitten Dream

Check against the official notice below — it lists the full affected range.

What happened

Two cylindrical table lamps sold under the brand name "Present Light" (model Present Light, GB7000.11-1999) with a Kitten Dream pattern pose an electric shock hazard due to multiple safety defects. The lamps lack proper cord anchorage, allowing the mains cable to be insufficiently protected against tension and twisting; the mains switch has no strain relief; the cable's cross-section measures less than 0.5 mm² instead of the required 0.75 mm², reducing mechanical strength; and bare wires with basic insulation are exposed where they enter the lamp housing. Additionally, the lamps are missing required safety markings such as manufacturer data, rated voltage, the Protection Class II symbol, and product identification information, and warnings are not provided in German. These lamps do not comply with the Low Voltage Directive or European standard EN 60598.

The authorities ordered withdrawal of these lamps from the market. The record does not specify what affected consumers should do with recalled products in their possession.

Written by software from the official notice below. Not reviewed by a lawyer.

Hazard

The product poses a risk of electric shock because:- the lamp has no cord anchorage and the mains cable conductors are therefore insufficiently protected against tension and twisting; - the mains switch does not have any strain relief;- the cross-section of the mains cable is less than 0.5 mm² (the required measurement is 0.75 mm²), which does not provide sufficient mechanical strength; - wires with basic insulation can be touched at the point they enter the lamp housing;- all inscriptions required by the standard, such as the manufacturer's data, the rated voltage, the Protection Class II-symbol, the type or order number and the rated power of the bulb are missing; - the warnings are not in German.The product does not comply with the Low Voltage Directive and the relevant European standard EN 60598.

What should I do?

Type of economic operator to whom the measure(s) were ordered: OtherCategory of measure(s): Withdrawal from the market ordered by the authorities.Date of entry into force: Unknown

Details from the source

2 identically designed portable table lamps (230V/25W), which differ only by the pattern on the lampshade. • protection class II design, • metal lamp housing, • plastic lampshade, • E14-lamp holder, • mains switch, • approximately 1.1m-long mains cable with moulded europlug, • Dimensions: height: approximately 27.5 cm, Ø approximately 10 cm. Model: Present Light, GB7000.11-1999 Notifying country: Germany

Source

Official record: EU Safety Gate ↗

Republished from the official source above; details can change — the source record controls.

Related recalls

All EU Safety Gate recalls

Hurt by this product? Start a free Case Check

ProductRisk is not a law firm and does not provide legal services or legal advice. ProductRisk is a free consumer product-safety information service operated by Plaintify, Inc., a technology company. If you ask to be connected with a law firm, any legal services are provided by that firm — not by ProductRisk or Plaintify.